Chiefland, Florida · USAdwight@paradoxip.comOffice: 352-493-0616Mobile: 352-949-4442

01 / Engineered flame protection

The right protection.
The details
to specify it.

Flame arresters, detonation flame arresters and anti-flashback burners. Product knowledge and engineering support, direct from Paradox IP LLC.

Find product documents
Blue Model C-8E-GD-CS-C-DPT flame arrester installed in a process piping systemMODEL C-8E-GD-CS-C-DPT
Installed Model C-8E-GD-CS-C-DPTView Model C-GD cut sheet
35+Years of product development

Founder-led engineering. Dwight Brooker has developed detonation flame-arrester technology since 1989. Paradox IP LLC carries that product knowledge forward through manufacturing, service and application support.

Talk to Dwight

02 / Application-specific engineering

Custom-Engineered
Flame Arresters

Specialized flame-protection solutions developed around the service, installation and performance requirements of demanding applications.

Selected custom programs

Space systems Naval applications Hydrogen/air service

Multiple Model C-2C-GCtH-S-S hydrogen detonation flame arresters for SHINE
USCG approvedHydrogen detonation flame arrester
Project 03Medical isotope production

SHINE

Model C-2C-GCtH-S-S

A USCG-approved hydrogen detonation flame arrester custom-engineered for SHINE for use in a medical radioactive-isotope project. This model is for hydrogen/air mixtures with a maximum experimental safe gap (MESG) of 0.28 mm and larger.

Project recordPhotograph added · Cut sheet and flow curve to follow

Additional project photographs, cut sheets and flow curves will be added to these product records as they become available.

03 / Protected customer engineering

Flame Arrester
Selection Suite

A guided workspace for application intake, gas and vapor review, preliminary model selection, pressure-drop comparison, and customer-ready PDF records.

Register or sign in
Controlled access
  1. Verify identitySign in with a verified email.
  2. Submit company detailsParadox reviews every request.
  3. Accept current TermsAcceptance is recorded by version.
  4. Use the protected SuiteAccess can be revoked at any time.

Private engineering records and original approval or acceptance letters are not included in the customer portal.

04 / Product & technical documents

Find the model.
Get the details.

Cut sheets, flow curves, application data, testing documents and engineering references in one place.

125 documents · All documents

PDF · View or save a copy
Model A-BRN flow curves

Model A-BRN · Anti-Flashback Burners

Air-flow capacity versus pressure drop for anti-flashback burners. Choose the model size or configuration required for your application review.

6 curves available

Series A flow curves

Series A · Gas Group B (IIC)

Air-flow capacity versus pressure drop for in-line deflagration flame arresters. Choose the model size or configuration required for your application review.

7 curves available

Series A flow curves

Series A · Gas Group C (IIB)

Air-flow capacity versus pressure drop for in-line deflagration flame arresters. Choose the model size or configuration required for your application review.

9 curves available

Series A flow curves

Series A · Gas Group D (IIA)

Air-flow capacity versus pressure drop for in-line deflagration flame arresters. Choose the model size or configuration required for your application review.

18 curves available

Series B flow curves

Series B · Gas Group D (IIA)

Air-flow capacity versus pressure drop for high-pressure deflagration flame arresters. Choose the model size or configuration required for your application review.

8 curves available

Series C flow curves

Series C · Gas Group B (IIC)

Air-flow capacity versus pressure drop for detonation flame arresters. Choose the model size or configuration required for your application review.

9 curves available

Series C flow curves

Series C · Gas Group C (IIB)

Air-flow capacity versus pressure drop for detonation flame arresters. Choose the model size or configuration required for your application review.

12 curves available

Series C flow curves

Series C · Gas Group D (IIA)

Air-flow capacity versus pressure drop for detonation flame arresters. Choose the model size or configuration required for your application review.

14 curves available

Series C-FH flow curves

Series C-FH · Gas Group B (IIC)

Air-flow capacity versus pressure drop for detonation flame arresters. Choose the model size or configuration required for your application review.

8 curves available

Series C-FH flow curves

Series C-FH · Gas Group C (IIB)

Air-flow capacity versus pressure drop for detonation flame arresters. Choose the model size or configuration required for your application review.

11 curves available

Series C-FH flow curves

Series C-FH · Gas Group D (IIA)

Air-flow capacity versus pressure drop for detonation flame arresters. Choose the model size or configuration required for your application review.

12 curves available

Technical documents retain their stated technical revision dates. Company and contact details have been updated. Confirm the current revision, approval status and application suitability with Paradox IP LLC before specification or installation.

Ask engineering

05 / Direct engineering support

Start with
your application.

For model selection, replacement elements or a quote, send your vapor composition, operating conditions, pipe size and a simple layout.

Independent sales representatives

CN China

Hangzhou Paladox Environmental Protection Technology Co., LTD

9 Liansheng Road, Wuchang Street,
Yuhang District, Hangzhou City,
Zhejiang, China
Mobile+86 13255185881

For sales in the USA and countries without a listed representative, contact Paradox IP LLC directly.